Sign In | Join Free | My himfr.com
Home > Perkins Diesel Generator >

250 KVA AC 3 Phase Silent Diesel Generator 50HZ Frequency Brushless

    Buy cheap 250 KVA AC 3 Phase Silent Diesel Generator 50HZ Frequency Brushless from wholesalers
     
    Buy cheap 250 KVA AC 3 Phase Silent Diesel Generator 50HZ Frequency Brushless from wholesalers
    • Buy cheap 250 KVA AC 3 Phase Silent Diesel Generator 50HZ Frequency Brushless from wholesalers
    • Buy cheap 250 KVA AC 3 Phase Silent Diesel Generator 50HZ Frequency Brushless from wholesalers
    • Buy cheap 250 KVA AC 3 Phase Silent Diesel Generator 50HZ Frequency Brushless from wholesalers
    • Buy cheap 250 KVA AC 3 Phase Silent Diesel Generator 50HZ Frequency Brushless from wholesalers

    250 KVA AC 3 Phase Silent Diesel Generator 50HZ Frequency Brushless

    Ask Lasest Price
    Brand Name : BOSSPOWER
    Model Number : BS-P250
    Certification : CE
    Price : Negotiable
    Payment Terms : L/C, T/T
    Supply Ability : 100 Sets per Month
    Delivery Time : About 30 days after receiving deposit or original L/C.
    • Product Details
    • Company Profile

    250 KVA AC 3 Phase Silent Diesel Generator 50HZ Frequency Brushless

    Heavy duty AC 3 Phase water cooled silent 250 kva perkins diesel generator


    Basic Configuration

    1 . Exhaust silencer 2 . Flexible pipes 3 . Starting battery 4 . Starting Charger 5 . Cooling radiator

    6 . Battery Wires 7 . Base frame 8 . Main circuit breaker 9 . AVR 10 . Manual books 11 . Control box

    12 . Switch-box 13 . Genset wooden


    Optional Supply :


    1 . ATS ( Automatic transfer system )

    2 . AMF Panel

    3 . Silent canopy ( for silent type only )

    4 . Fuel Tank ( 8 hours running )

    5 . Four Protection ( high temperature auto shutdown , overload automatic shutdown ,

    low oil pressure automatic shutdown , automatic shutdown phase )

    6 . Parallel system

    7 . Remote system

    8 . Trailer type

    9 . Soundproof / water proof


    10 . Lighting tower


    Perkins is a famous engine manufacturer, which acquired the world’s leading brand Rolls-Royce in nineties

    of last century. Since the engines produced are used in the assembly of Rolls-Royce cars, it is world-renowned.

    Perkins engines have excellent stability, reliability and durability, being widely used in the communication,

    industry, outdoor works, mining, the rescue, military and other fields.


    PRODUCT DESCRIPTION
    Genset ModelBS-P250
    Prime Power (kw/kva)200/250Standby Power(kw/kva)220/275
    Voltage (v)400/230Rated Speed (rpm)1500
    Frequency (Hz)50Rated Current (A)360.8
    Connection:3 phase 4 wirePower Factor:0.8
    Engine Model:1506A-E88TAG3Alternator Model:UCDI274K
    Net Weight (kgs)-Open2600Net Weight (kgs)-Silent3100
    Dimensions (mm)-Open2650X955X1680Dimensions (mm)-Silent3850X1360X1900
    Engine Parameter:

    Manufacturer/Model

    Air Intake System: Fuel System

    Cylinder numbers

    Displacement

    Bore x Stroke

    Compression Ratio

    Max. Power

    Governing System

    Perkins,1506A-E88TAG3 , 4 stroke
    Turbocharged, Air to air aftercooled

    HEUI fuel system

    6 cylinders

    8.8L

    112 x 149 mm

    16.1 : 1

    244KW

    Electronic

    Exhaust System

    Exhaust gas flow

    Exhaust temperature

    Max. Allowed Back Pressure

    --m3/min

    -- ℃

    -- KPa

    Intake System

    Max. Allowed Pressure

    Clean filter

    Dirty filter

    Combustion air flow


    -- kPa

    -- kPa

    -- m3/min

    Fuel System

    100% Load (Prime)

    75% Load(Prime)

    50% Load (Prime)

    56L/h

    42L/h

    29L/h

    Lube System

    Total Oil Capacity

    Oil Consumption(% of fuel)

    Max. Total system Oil Capacity

    Oil Pressure at rated speed

    41 L

    < 0.1

    -- L

    -- kPa

    Cooling system

    Total Coolant Capacity

    Thermostat

    Max. Water Temperature

    29.6 L

    87-98℃

    107℃

    Alternator Parameter: Basic Information

    The alternators meet the standards of:

    GB755, BS5000, VDE00530, NEMAMG1-22,IED34-1,CSA22.2 and AS1350

    Technical Data:

    Manufacturer

    Phases

    Connection

    Bearing numbers

    Power Factor

    Protection Class

    Altitude Condition

    Excitation

    Insulation class/Temp. rise class

    Tel. Influence Factor TIF

    Tel. Harmonic Factor THF

    Steady State Voltage Regulation

    Alternator Capacity

    Efficiency

    Cooling Air Flow

    STAMFORD,UCDI274K

    3

    3 phase 4 wire, Y type

    1

    0.8

    IP23

    ≤1000M

    Brushless, self-excitation

    H / H

    <50

    <2%

    ≤±1%

    250KVA

    92.7%

    0.514m³/s


    Features of genset :


    1 . Powered by heavy duty industrial diesel engines , Cummins , Perkins , Isuzu , Duetz or China brand diesel engine can be chosen.


    2 . Radiator 40 degree or 50 degree max, fans are driven by belt , with safety guard .


    3 . 12/24DC start motor and storage battery .


    4 . Brushless , self-excited , IP22/23 , insulation H alternator .


    5 . Absorber to reduce vibration .


    6 . Dry type air filter , fuel filter , oil filter .


    7 . Main line circuit breaker .


    8 . Control system : key start control panel as standard , digital auto start or ATS system is optional .


    9 . 8 hours operation base fuel tank .


    10 . High efficient muffler to reduce noise .


    11 . Ripple flex exhaust pipe , exhaust siphon and flange etc.


    12 . Genset type: open type or soundproof/silent type, or trailer type .


    13 . Maintenance and operation manual for generator , engine and alternator , engine parts catalog , quality certificate , etc .


    250 KVA AC 3 Phase Silent Diesel Generator 50HZ Frequency Brushless

    250 KVA AC 3 Phase Silent Diesel Generator 50HZ Frequency Brushless

    FAQ

    Q : How to choose the power ?
    A : Collect all power of your equipments , take the current into your consideration .
    Q : What is the difference between Prime power and Standby power ?
    A : Prime power is 12hours continous power , one hour 10% over load in every 12 running hours is allowed .
    Standby power is the limit value of maximum output for emergency use . Overloading is prohibited

    Q : What is your payment term ?
    A : 30% T/T in advance , the rest payment before shipment . Or irrevocable L/C .
    Q : What is your lead time ?
    A : About 30 days after receiving deposit or original L/C . But if your order with some special design , then the delivery time is longer .


    Quality 250 KVA AC 3 Phase Silent Diesel Generator 50HZ Frequency Brushless for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: FUJIAN BOSS ELECTRICAL MACHINERY CO.,LTD.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)